Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
2.
Sci Rep ; 13(1): 8118, 2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208380

RESUMO

Cardiovascular imaging studies provide a multitude of structural and functional data to better understand disease mechanisms. While pooling data across studies enables more powerful and broader applications, performing quantitative comparisons across datasets with varying acquisition or analysis methods is problematic due to inherent measurement biases specific to each protocol. We show how dynamic time warping and partial least squares regression can be applied to effectively map between left ventricular geometries derived from different imaging modalities and analysis protocols to account for such differences. To demonstrate this method, paired real-time 3D echocardiography (3DE) and cardiac magnetic resonance (CMR) sequences from 138 subjects were used to construct a mapping function between the two modalities to correct for biases in left ventricular clinical cardiac indices, as well as regional shape. Leave-one-out cross-validation revealed a significant reduction in mean bias, narrower limits of agreement, and higher intraclass correlation coefficients for all functional indices between CMR and 3DE geometries after spatiotemporal mapping. Meanwhile, average root mean squared errors between surface coordinates of 3DE and CMR geometries across the cardiac cycle decreased from 7 ± 1 to 4 ± 1 mm for the total study population. Our generalised method for mapping between time-varying cardiac geometries obtained using different acquisition and analysis protocols enables the pooling of data between modalities and the potential for smaller studies to leverage large population databases for quantitative comparisons.


Assuntos
Ecocardiografia Tridimensional , Humanos , Ecocardiografia Tridimensional/métodos , Imageamento por Ressonância Magnética , Viés , Ventrículos do Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Função Ventricular Esquerda , Volume Sistólico
3.
Physiol Rep ; 11(3): e15599, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36750180

RESUMO

The aim of this study was to investigate cardiomyocyte Ca2+ handling and contractile function in freshly excised human atrial tissue from diabetic and non-diabetic patients undergoing routine surgery. Multicellular trabeculae (283 ± 20 µm in diameter) were dissected from the endocardial surface of freshly obtained right atrial appendage samples from consenting surgical patients. Trabeculae were mounted in a force transducer at optimal length, electrically stimulated to contract, and loaded with fura-2/AM for intracellular Ca2+ measurements. The response to stimulation frequencies encompassing the physiological range was recorded at 37°C. Myofilament Ca2+ sensitivity was assessed from phase plots and high potassium contractures of force against [Ca2+ ]i . Trabeculae from diabetic patients (n = 12) had increased diastolic (resting) [Ca2+ ]i (p = 0.03) and reduced Ca2+ transient amplitude (p = 0.04) when compared to non-diabetic patients (n = 11), with no difference in the Ca2+ transient time course. Diastolic stress was increased (p = 0.008) in trabeculae from diabetic patients, and peak developed stress decreased (p ≤ 0.001), which were not accounted for by reduction in the cardiomyocyte, or contractile protein, content of trabeculae. Trabeculae from diabetic patients also displayed diminished myofilament Ca2+ sensitivity (p = 0.018) compared to non-diabetic patients. Our data provides evidence of impaired calcium handling during excitation-contraction coupling with resulting contractile dysfunction in atrial tissue from patients with type 2 diabetes in comparison to the non-diabetic. This highlights the importance of targeting cardiomyocyte Ca2+ homeostasis in developing more effective treatment options for diabetic heart disease in the future.


Assuntos
Fibrilação Atrial , Diabetes Mellitus Tipo 2 , Humanos , Cálcio/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Fibrilação Atrial/metabolismo , Contração Miocárdica/fisiologia , Átrios do Coração/metabolismo , Cálcio da Dieta/metabolismo , Retículo Sarcoplasmático/metabolismo
4.
Front Cardiovasc Med ; 9: 1016703, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36704465

RESUMO

Segmentation of the left ventricle (LV) in echocardiography is an important task for the quantification of volume and mass in heart disease. Continuing advances in echocardiography have extended imaging capabilities into the 3D domain, subsequently overcoming the geometric assumptions associated with conventional 2D acquisitions. Nevertheless, the analysis of 3D echocardiography (3DE) poses several challenges associated with limited spatial resolution, poor contrast-to-noise ratio, complex noise characteristics, and image anisotropy. To develop automated methods for 3DE analysis, a sufficiently large, labeled dataset is typically required. However, ground truth segmentations have historically been difficult to obtain due to the high inter-observer variability associated with manual analysis. We address this lack of expert consensus by registering labels derived from higher-resolution subject-specific cardiac magnetic resonance (CMR) images, producing 536 annotated 3DE images from 143 human subjects (10 of which were excluded). This heterogeneous population consists of healthy controls and patients with cardiac disease, across a range of demographics. To demonstrate the utility of such a dataset, a state-of-the-art, self-configuring deep learning network for semantic segmentation was employed for automated 3DE analysis. Using the proposed dataset for training, the network produced measurement biases of -9 ± 16 ml, -1 ± 10 ml, -2 ± 5 %, and 5 ± 23 g, for end-diastolic volume, end-systolic volume, ejection fraction, and mass, respectively, outperforming an expert human observer in terms of accuracy as well as scan-rescan reproducibility. As part of the Cardiac Atlas Project, we present here a large, publicly available 3DE dataset with ground truth labels that leverage the higher resolution and contrast of CMR, to provide a new benchmark for automated 3DE analysis. Such an approach not only reduces the effect of observer-specific bias present in manual 3DE annotations, but also enables the development of analysis techniques which exhibit better agreement with CMR compared to conventional methods. This represents an important step for enabling more efficient and accurate diagnostic and prognostic information to be obtained from echocardiography.

5.
Front Cardiovasc Med ; 8: 728205, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34616783

RESUMO

Aims: Left ventricular (LV) volumes estimated using three-dimensional echocardiography (3D-echo) have been reported to be smaller than those measured using cardiac magnetic resonance (CMR) imaging, but the underlying causes are not well-understood. We investigated differences in regional LV anatomy derived from these modalities and related subsequent findings to image characteristics. Methods and Results: Seventy participants (18 patients and 52 healthy participants) were imaged with 3D-echo and CMR (<1 h apart). Three-dimensional left ventricular models were constructed at end-diastole (ED) and end-systole (ES) from both modalities using previously validated software, enabling the fusion of CMR with 3D-echo by rigid registration. Regional differences were evaluated as mean surface distances for each of the 17 American Heart Association segments, and by comparing contours superimposed on images from each modality. In comparison to CMR-derived models, 3D-echo models underestimated LV end-diastolic volume (EDV) by -16 ± 22, -1 ± 25, and -18 ± 24 ml across three independent analysis methods. Average surface distance errors were largest in the basal-anterolateral segment (11-15 mm) and smallest in the mid-inferoseptal segment (6 mm). Larger errors were associated with signal dropout in anterior regions and the appearance of trabeculae at the lateral wall. Conclusions: Fusion of CMR and 3D-echo provides insight into the causes of volume underestimation by 3D-echo. Systematic signal dropout and differences in appearances of trabeculae lead to discrepancies in the delineation of LV geometry at anterior and lateral regions. A better understanding of error sources across modalities may improve correlation of clinical indices between 3D-echo and CMR.

6.
Front Physiol ; 12: 724372, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34690801

RESUMO

The disrupted organisation of the ryanodine receptors (RyR) and junctophilin (JPH) is thought to underpin the transverse tubule (t-tubule) remodelling in a failing heart. Here, we assessed the nanoscale organisation of these two key proteins in the failing human heart. Recently, an advanced feature of the t-tubule remodelling identified large flattened t-tubules called t-sheets, that were several microns wide. Previously, we reported that in the failing heart, the dilated t-tubules up to ~1 µm wide had increased collagen, and we hypothesised that the t-sheets would also be associated with collagen deposits. Direct stochastic optical reconstruction microscopy (dSTORM), confocal microscopy, and western blotting were used to evaluate the cellular distribution of excitation-contraction structures in the cardiac myocytes from patients with idiopathic dilated cardiomyopathy (IDCM) compared to myocytes from the non-failing (NF) human heart. The dSTORM imaging of RyR and JPH found no difference in the colocalisation between IDCM and NF myocytes, but there was a higher colocalisation at the t-tubule and sarcolemma compared to the corbular regions. Western blots revealed no change in the JPH expression but did identify a ~50% downregulation of RyR (p = 0.02). The dSTORM imaging revealed a trend for the smaller t-tubular RyR clusters (~24%) and reduced the t-tubular RyR cluster density (~35%) that resulted in a 50% reduction of t-tubular RyR tetramers in the IDCM myocytes (p < 0.01). Confocal microscopy identified the t-sheets in all the IDCM hearts examined and found that they are associated with the reticular collagen fibres within the lumen. However, the size and density of the RyR clusters were similar in the myocyte regions associated with t-sheets and t-tubules. T-tubule remodelling is associated with a reduced RyR expression that may contribute to the reduced excitation-contraction coupling in the failing human heart.

7.
Clin Exp Pharmacol Physiol ; 48(1): 137-146, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32854154

RESUMO

Acute cellular rejection after cardiac transplantation surgery is routinely monitored by pathological assessment of haematoxylin and eosin (H&E) histology of endomyocardial biopsies (EMB). Unfortunately, there is considerable variation in the diagnosis of rejection that has been attributed to the subjectivity involved in assessing the degree of (a) inflammatory infiltrate and (b) myocyte damage. In this work, we sought to investigate the potential of high contrast confocal microscopy for numerically assessing inflammatory infiltrate and myocyte damage in EMB histology. Confocal microscopy was used to capture images from EMB fluorescently labelled for nuclei (DAPI), f-actin (phalloidin), troponin-T (anti-body), and extracellular matrix and cell border (wheat germ agglutinin). Images from 28 biopsy procedures were captured. Standard pathological grading of H&E histology identified the following rejection gradings: 6 0R, 16 1R, 6 2R and no 3R. Confocal imaging was able to identify equivalent features of rejection provided by H&E histology but at higher contrast facilitating quantification. Lymphocytic infiltrate was calculated as the ratio of non-myocyte nuclei to total nuclei. This metric was found to be significantly higher in the biopsies from 2R patients compared to both 1R and 0R patients (P < .05). Myocyte damage was quantified as the loss of troponin-T labelling normalised to f-actin labelling. This metric of myocyte damage found significantly lower amounts of troponin-T in the biopsies from 2R patients compared to those with a 0R rejection grading (P < .05). Confocal imaging and simple image processing routines show potential for numerically assessing both inflammatory infiltrate and myocyte damage in endomyocardial biopsy.

8.
Heart Lung Circ ; 29(3): 368-373, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30948328

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an alternative and effective contemporary intervention to surgical aortic valve replacement (SAVR) for patients with severe aortic valve disease at increased surgical risk. Guidelines recommend a multidisciplinary "Heart Team" (MHT) review of patients considered for a TAVI procedure, but this has been little studied. We reviewed the characteristics, treatments and outcomes of such patients reviewed by the MHT at our centre. METHODS: Data on consecutive patients with severe aortic valve stenosis discussed by the Auckland City Hospital MHT from June 2011 to August 2016 were obtained from clinical records. Patient characteristics, treatment and outcomes were analysed using standard statistical methods. RESULTS: Over the 5-year period 243 patients (mean age 80.2 ± 8.0 years, 60% male) were presented at the MHT meeting. TAVI was recommended for 200, SAVR for 26 and medical therapy for 17 patients, with no significant difference in mean age (80.2 ± 8.3, 80.4 ± 6.1, 80.4 ± 7.3 years, respectively) or EuroSCORE II (6.5 ± 4.7%, 5.3 ± 3.6%, 6.7 ± 4.3%, respectively). Over time, there was an increase in the number of patients discussed and treated, with no change in their mean age, but the mean EuroSCORE II significantly decreased (TAVI p = 0.026, SAVR p = 0.004). Survival after TAVI and SAVR was similar to that of the age-matched general population, but superior to medical therapy p = 0.002 (93% (n = 162), 84% (n = 21) and 73% (n = 18) at one year and 85% (n = 149), 84% (n = 21) and 54% (n = 13) at 2 years, respectively). CONCLUSIONS: An increasing number of patients were discussed at the MHT meeting with the majority undergoing TAVI, with a similar age and EuroSCORE II to those allocated SAVR or medical therapy. Survival following TAVI and SAVR was superior to medical therapy and similar to the age-matched general population. These findings suggest that the MHT process is robust, consistent and appropriately allocating a limited treatment resource.


Assuntos
Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida
9.
Intern Med J ; 49(3): 388-391, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30897671

RESUMO

The natural history of a systemic right ventricle after an atrial switch procedure has yet to be fully characterised. We describe the case of the longest surviving patient at our institution who underwent a Mustard Baffle correction for dextro-transposition of great arteries in childhood. Over following decades he was reviewed regularly with deteriorating systemic right ventricle function. At around 50 years of age he developed worsening heart failure on maximal medical therapy. He was subsequently assessed for cardiac transplantation which he underwent successfully at the age of 55 years.


Assuntos
Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/fisiopatologia , Transposição dos Grandes Vasos/fisiopatologia , Disfunção Ventricular Direita/fisiopatologia , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Transplante de Coração , Humanos , Masculino , Pessoa de Meia-Idade , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/cirurgia , Resultado do Tratamento , Disfunção Ventricular Direita/etiologia
13.
JACC Case Rep ; 1(5): 713-717, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-34316916

RESUMO

An incidental finding of a large left ventricular outflow tract pseudoaneurysm in a 74-year-old man, with high surgical risk, was managed with a novel, fully percutaneous, left ventricular apical approach. The pseudoaneurysm defect and the apical puncture site were successfully closed with Amplatzer septal occluders with successful positioning, as demonstrated on cardiac computed tomography at 6 weeks follow-up. (Level of Difficulty: Intermediate.).

14.
Sci Rep ; 8(1): 2957, 2018 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-29440728

RESUMO

Heart failure (HF) is defined by compromised contractile function and is associated with changes in excitation-contraction (EC) coupling and cardiomyocyte organisation. Tissue level changes often include fibrosis, while changes within cardiomyocytes often affect structures critical to EC coupling, including the ryanodine receptor (RyR), the associated protein junctophilin-2 (JPH2) and the transverse tubular system architecture. Using a novel approach, we aimed to directly correlate the influence of structural alterations with force development in ventricular trabeculae from failing human hearts. Trabeculae were excised from explanted human hearts in end-stage failure and immediately subjected to force measurements. Following functional experiments, each trabecula was fixed, sectioned and immuno-stained for structural investigations. Peak stress was highly variable between trabeculae from both within and between failing hearts and was strongly correlated with the cross-sectional area occupied by myocytes (MCSA), rather than total trabecula cross-sectional area. At the cellular level, myocytes exhibited extensive microtubule densification which was linked via JPH2 to time-to-peak stress. Trabeculae fractional MCSA variability was much higher than that in adjacent free wall samples. Together, these findings identify several structural parameters implicated in functional impairment in human HF and highlight the structural variability of ventricular trabeculae which should be considered when interpreting functional data.


Assuntos
Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Contração Miocárdica , Miócitos Cardíacos/patologia , Fenômenos Biomecânicos , Humanos , Espaço Intracelular/metabolismo , Microtúbulos/metabolismo
15.
Open Heart ; 4(2): e000680, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29118997

RESUMO

The ideal stent must fulfil a broad range of technical requirements. Stents must be securely crimped onto the delivery balloon and, in this form, must have a low profile and be sufficiently flexible to facilitate deliverability to the lesion site without distortion or displacement. Following expansion, stents must exert sufficient radial force on the vessel wall to overcome lesion resistance and elastic recoil. To achieve an optimal lumen diameter, the lesion must be uniformly and adequately scaffolded, with minimal tissue prolapse between struts but without compromising side-branch access. Furthermore, the deployed stent must conform to the vessel curvature to minimise vessel distortion, particularly at the stent edges. Radio-opacity is also important to guide safe positioning, adequate deployment and postdilataion and to permit assessment of optimal stent expansion. Equally though, the stent lumen must also be sufficiently visible to allow radiographic assessment of flow dynamics and restenosis. Efforts to optimise one characteristic of stent design may have detrimental effects on another. Thus, currently available stents all reflect a compromise between competing desirable features and have subtle differences in their performance characteristics. Striving to achieve stents with optimal deliverability, conformability and radial strength led to a reduction in longitudinal strength. The importance of this parameter was highlighted by complications occurring in the real-world setting where percutaneous coronary intervention is often undertaken in challenging anatomy. This review focuses on aspects of stent design relevant to longitudinal strength.

16.
Cardiovasc Res ; 113(8): 879-891, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-28444133

RESUMO

AIMS: In heart failure transverse-tubule (t-tubule) remodelling disrupts calcium release, and contraction. T-tubules in human failing hearts exhibit increased labelling by wheat germ agglutinin (WGA), a lectin that binds to the dystrophin-associated glycoprotein complex. We hypothesized changes in this complex may explain the increased WGA labelling and contribute to t-tubule remodelling in the failing human heart. In this study we sought to identify the molecules responsible for this increased WGA labelling. METHODS AND RESULTS: Confocal and super-resolution fluorescence microscopy and proteomic analyses were used to quantify left ventricle samples from healthy donors and patients with idiopathic dilated cardiomyopathy (IDCM). Confocal microscopy demonstrated both WGA and dystrophin were located at t-tubules. Super-resolution microscopy revealed that WGA labelling of t-tubules is largely located within the lumen while dystrophin was restricted to near the sarcolemma. Western blots probed with WGA reveal a 5.7-fold increase in a 140 kDa band in IDCM. Mass spectrometry identified this band as type VI collagen (Col-VI) comprised of α1(VI), α2(VI), and α3(VI) chains. Pertinently, mutations in Col-VI cause muscular dystrophy. Western blotting identified a 2.4-fold increased expression and 3.2-fold increased WGA binding of Col-VI in IDCM. Confocal images showed that Col-VI is located in the t-tubules and that their diameter increased in the IDCM samples. Super-resolution imaging revealed Col-VI was restricted to the t-tubule lumen where increases were associated with displacement in the sarcolemma as identified from dystrophin labelling. Samples were also labelled for type I, III, and IV collagen. Both confocal and super-resolution imaging identified that these collagens were also present within t-tubule lumen. CONCLUSION: Increased expression and labelling of collagen in IDCM samples indicates fibrosis may contribute to t-tubule remodelling in human heart failure.


Assuntos
Colágeno/metabolismo , Insuficiência Cardíaca/metabolismo , Miocárdio/metabolismo , Miócitos Cardíacos/metabolismo , Sarcolema/metabolismo , Adulto , Distrofina/metabolismo , Feminino , Insuficiência Cardíaca/patologia , Ventrículos do Coração/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Miócitos Cardíacos/patologia , Proteômica/métodos , Sarcolema/patologia
17.
J Card Surg ; 32(3): 172-176, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28198037

RESUMO

BACKGROUND: Risk stratification for mitral valve repair or replacement (MVR) is important in the decision-making for treating several mitral valve disease but is rarely studied. We compared the prognostic utility of EuroSCORE, EuroSCORE II, and Society of Thoracic Surgeons (STS) Score for MVR. METHODS: The three scores were retrospectively calculated for consecutive patients undergoing isolated MVR at Auckland City Hospital during 2005-2012 and their discrimination and calibration for mortality and morbidities assessed. RESULTS: There were 408 patients (mitral valve repair 48.1% and replacement 51.9%) followed-up for 6.0 ± 2.6 years. The operative mortality was 2.5%. Mean EuroSCORE, EuroSCORE II, and STS Score were 7.6%, 3.4%, and 3.5%. C-statistics were 0.844, 0.817, and 0.850 for operative mortality. Hosmer-Lemeshow test p values were 0.076, 0.541, and 0.306, and Brier scores 0.0246, 0.0035, and 0.0075, respectively, for operative mortality. The numerically highest c-statistic for predicting complications include EuroSCORE for return to the operating room (c = 0.673); EuroSCORE II for stroke (c = 0.669) and mediastinitis (c = 0.801); and STS for renal failure (c = 0.828), ventilation >24 hours (c = 0.789), and composite morbidity (c = 0.732). The individual STS complication models for MVR had a numerically higher c-statistic only for stroke (c = 0.737). CONCLUSIONS: All scores discriminated mortality and most morbidities after MVR, although EuroSCORE over-estimated operative mortality. The STS Score was the best overall predictor of mortality and morbidity in the MVR cohort.


Assuntos
Valva Mitral/cirurgia , Adulto , Idoso , Estudos de Coortes , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Risco , Fatores de Tempo
18.
Int J Cardiol ; 236: 350-355, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28111053

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is considered for severe aortic valve disease at high and now intermediate risk for surgical aortic valve replacement. Risk stratification plays a critical role decision-making for intervention and modality. We compared the prognostic utility of surgical risk scores for TAVI in this meta-analysis. METHODS: MEDLINE, Embase, Cochrane and Web of Science databases from 1 January 1980 to 31 December 2015 were searched. Studies were systematically reviewed for inclusion, and data extracted for pooled analyses. RESULTS: Amongst 1688 articles searched, 47 full-text articles were screened and 24 studies (12,346 TAVI cases) included for analyses. Pooled c-statistics (95% confidence interval) for operative mortality were EuroSCORE 0.62 (0.57-0.67), EuroSCORE II 0.62 (0.59-0.66), STS Score 0.62 (0.59-0.65). Pooled calibration odds ratios (95%CI) were EuroSCORE 0.31 (0.25-0.38), EuroSCORE II 1.26 (1.06-1.51), STS 0.95 (0.72-1.27). C-statistics (95%CI) for 1-year mortality were EuroSCORE 0.62 (0.57-0.67), EuroSCORE II 0.66 (0.61-0.71) and STS Score 0.58 (0.53-0.64). CONCLUSION: Surgical risk scores at most modestly discriminated operative and 1-year mortality. The EuroSCORE grossly over-estimated operative mortality while the EuroSCORE II and STS Scores fitted better to TAVI outcomes with their own limitations. There is a need for the development and validation of TAVI-specific risk models.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/mortalidade , Humanos , Estudos Observacionais como Assunto , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/mortalidade
19.
Heart Lung Circ ; 26(1): 82-87, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27432737

RESUMO

BACKGROUND: With the introduction of transcatheter aortic valve implantation (TAVI), there is increasing interest in evaluating outcomes of aortic valve replacement (AVR) with or without (+/-) concurrent coronary artery bypass grafting (CABG) particularly in high-risk patients. We reviewed the characteristics and outcomes of octogenarians undergoing isolated AVR and AVR+CABG. METHODS: All patients 80 years of age or older undergoing AVR+/-CABG at Auckland City Hospital during 2005-2012 were included, and their characteristics and outcomes analysed. RESULTS: There were 93 and 104 octogenarians respectively undergoing isolated AVR and AVR+CABG with mean follow-up of 4.4+/-2.2 years and 4.1+/-2.3 years. Significant differences in baseline and operative characteristics contributed to higher EuroSCORE II (5.9 vs 6.4%, P=0.016) and STS Score (4.9 vs 6.9%, P<0.001) for AVR+CABG patients. They also had a significantly higher rate of 30-day mortality (0.0% vs 6.7%, P=0.015) and prolonged ventilation>24hours (10.7% vs 23.1%, P<0.001), but not composite morbidity (P=0.248) or stroke (P=0.709). Long-term survival was similar at one, three and five years; 94.6%, 82.6% and 73.0% for AVR and 91.3%, 86.1% and 67.6% for AVR+CABG. Independent predictors of 30-day mortality included reduced creatinine clearance and history of myocardial infarction. CONCLUSION: AVR+CABG had significantly higher but acceptable 30-day mortality in octogenarians than AVR. We have identified prognostic factors important in the decision-making of treatment modality, where age alone should not preclude surgery.


Assuntos
Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Complicações Pós-Operatórias/mortalidade , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Ponte de Artéria Coronária/métodos , Feminino , Seguimentos , Humanos , Masculino , Fatores de Tempo
20.
Heart Lung Circ ; 25(11): 1118-1123, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27139115

RESUMO

BACKGROUND: Aortic valve replacement (AVR) and/or coronary artery bypass grafting (CABG) make up the majority of cardiac surgery with increasing demand as the population ages. Accuracy of risk stratification is important, in predicting adverse outcomes and selecting modality of intervention, but has been rarely studied for the combined AVR+CABG operation. We compared the prognostic utility of EuroSCORE, EuroSCORE II and Society of Thoracic Surgeons' (STS) Score for AVR+CABG. METHODS: All patients (n=450) undergoing AVR+CABG at Auckland City Hospital during 2005-2012 with mean follow-up of 4.7+/-2.5 years were included. The three risk scores were calculated and their discrimination and calibration for mortality and morbidities assessed. RESULTS: Operative mortality was 6.4% (29), and mean scores were EuroSCORE 12.5+/-11.1%, EuroSCORE II 6.6+/-6.1% and STS Score 5.5+/-4.4%. C-statistics were 0.587, 0.669 and 0.699 respectively for operative mortality, Hosmer-Lemeshow test P-values were 0.064, 0.718 and 0.567, and Brier Score 0.716, 0.585 and 0.588. Independent predictors of operative mortality were history of myocardial infarction and impaired renal function. Society of Thoracic Surgeons' score also was the most accurate score for predicting mortality during follow-up (c=0.663), composite morbidity (c=0.627), stroke (c=0.642), prolonged ventilation>24hours (c=0.642), and return to theatre (c=0.612). CONCLUSION: The STS score has the best discriminative ability for mortality and the majority of complications after AVR+CABG, while its calibration was similar to EuroSCORE II and superior to EuroSCORE. It should therefore be used for risk stratification and when considering surgical versus percutaneous intervention in those with concurrent aortic valve and coronary artery disease.


Assuntos
Valva Aórtica/cirurgia , Ponte de Artéria Coronária/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Taxa de Sobrevida
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...